BACnet Thermostat
|
EXL01611 BACnet Air Handler with Staged Heat/Cool and Digital Scroll |
- Air Handler Units - Rooftop, Split, Indoor
- BACnet communications
- Modulating Digital Scroll Compressor Cooling 1-5Vdc
- 1 to 2 Stage Cooling and 1 to 2 Stage Heating
- Modulating Heat Output 0-10Vdc
- The Digital Scroll Compressor Output stages 1 or 2 compressors while controlling the Digital Scroll compressor (usually 1st stage) output using a 1-5 Vdc signal to control the unloading. This control is seen on many products utilizing Digital Scroll compressors from manufactures like AAON, United Cool Air, Addison and others.
|
|
|
Your Price: $158.00 |
|
|
|
EXL01615 RTU w/ Humidify/Dehumidify Sequence |
- Roof Top Unit / Fan Coil /Make Up Air Unit
- 1 Stage Heat
- 1 Stage Cool
- Modulating Analog Heat
- Modulating Analog Cooling
- Humidify Command
- Dehumidify Sequence
- Hose Tower (RTU Functions are Off in this Mode)
- Runs Fan for Dehumidification
- Buttons Adjust Humidity Setpoint
- Fan Override Control
- Override Timer
- On/Off Function
- Options
- Duct Sensor
- Motion Sensors (Internal and External)
- External Room Sensor
- Internal Humidity Sensor
|
|
|
Your Price: $158.00 |
|
|
|
EXL01590 BACnet Airflow Velocity and CFM Measurement - Average |
- Airflow Velocity and Cubic Feet per Minute (CFM) Measurement
- 4 Thermo Anemometer Airflow Sensors included
- Measurement Ranges from 30 FPM to 4000 FPM
- Averaging of sensors with Total CFM
- Calibration Factor Adjustment
- OSA Monitoring option
- BACnet communications
- Damper Control
- Modulating Analog Output
- Floating Point
- Outside Air flow station with CFM measurement
- Exhaust Air flow station with CFM measurement
- Return Air flow station with CFM measurement
|
|
|
Your Price: $580.00 |
|
|
|
EXL01612 BACnet RTU Fan Coil Units Furnaces |
- Roof Top Units, Fan Coil Units, Furnaces, Exhaust Fans, Reheat Coils, and other heating and cooling applications
- Occupancy Monitoring
- 4-Pipe or 2-Pipe systems
- 4-Pipe Mode
- 2-Stage Heating or Cooling
- Modulating Heating and Cooling
- Floating/Tristate Heating or Cooling
- 2-Pipe Mode
- Digital Heating/Cooling
- Digital Radiation stage
- Adjustable time Valve Purge
|
|
|
Your Price: $158.00 |
|
|
|
EXL01613 BACnet AHU Controller with Economizer |
- Air Handler - Roof Top Unit or Indoor Air Handler
- BACnet Communications
- Staged Cooling
- Modulating Cooling Output PO/PC
- Economizer Control 0-10Vdc
- Modulating Heat Output 0-10Vdc or PO/PC
- Outputs are adjustable for 0-5Vdc or 2-10Vdc
- Mixed Air Temperature
- Supply Air Temperature
- Room Temperature
|
|
|
Your Price: $158.00 |
|
|
|